A-QB-1300Series

High-speed processing of a variety of crystal blanks, from ultra-small to large sizes, etched and polished

Quartz blanks are fed from a hopper, and the position of the quartz blank is detected by an imaging device on the feeding rotor and transported to the measurement unit. The measurement unit automatically adjusts the air gap between the upper and lower electrodes, and the network analyzer realizes high-precision measurement and classification.

Model 1350
(1210 to 2520 compatible)
1300
(1612 to 3225 compatible)
1330
(For large products)
Measurement item

· Blank basic frequency
· Blank third harmonic frequency (Δf)
(Third harmonic measured value – Three times calculated value of fundamental frequency)
CI, spurious

Measurement frequency

10 to 180 MHz

Measuring instrument

Network analyzer board HC2000C(HUMO)

Measurement accuracy

± 100 ppm
20 MHz same blank 10 times repetition

Corresponding variety

L=0.7㎜ to 1.4㎜×0.4㎜ to 0.8㎜

① 2.0 mm × 1.3 mm to 1.4 mm × 1.0 mm
② 1.6 mm × 1.1 mm to 1.0 mm × 0.75 mm

① Round Work:φ5mm to 11mm
② Square Work:□5mm to 11mm

processing power

166 pcs/min 【0.36 sec / piece】
Including measuring time 75mS

100 pcs / min 【0.6 sec / piece】
Including measuring time 140 mS

60 pcs / min 【1.0 sec / piece】
Including measuring time 140 mS

Dimension

550(W) × 550(D) × 1600(H)mm

650(W) × 500(D) × 1600(H)mm

650(W) × 500(D) × 1600(H) mm

Classification

Binning: 45 ranks (including RI)
OK 1 to OK 39, + NG, -NG, CING
Spurious NG, RPLNG, RI

Binning: 45 ranks (including RI)
OK 1 to OK 39, + NG, -NG, CING
Spurious NG, RPLNG, RI

Binning: 24 ranks (including RI)
OK 1 to OK 18, + NG, -NG, CING
Spurious NG, RPLNG, RI

Power Supply

AC200V 50/60Hz 3A

Air Supply

0.4MPa(dry clean air)

* Because of interim specifications, there is a possibility of specification change without notice.

Flow of introduction