{"id":2284,"date":"2022-06-21T12:15:26","date_gmt":"2022-06-21T03:15:26","guid":{"rendered":"http:\/\/ctc-230148001434.kir.jp\/en\/?page_id=2284"},"modified":"2022-06-21T14:30:01","modified_gmt":"2022-06-21T05:30:01","slug":"vim-02","status":"publish","type":"page","link":"https:\/\/www.humo.co.jp\/en\/products\/measuring_instrument\/vim-02","title":{"rendered":"VIM-02"},"content":{"rendered":"<div class=\"content-main\">\r\n\t<div class=\"content-inner\">\r\n\t\t<h3 class=\"c-headline02\">Voltmeter VIM-02<\/h3>\r\n\t\t<p class=\"c-text u-mb-50\">The VIM-02 withstand voltage meter is the ideal instrument for measuring leakage currents in MLCCs and other devices.\r\nIt is capable of outputting high voltage suitable for high-voltage MLCCs and high current suitable for high-capacity MLCCs, making it applicable to a wide range of products.\r\nWith 8 channels each for pre-charge, discharge, and measurement, it is suitable for installation in an automatic machine with multi-channel stations.<br>\r\nIn addition, each channel is equipped with an independent contact check function as standard for reliable measurement.\r\n<\/p>\r\n\t\t<div class=\"products-print u-mb-40\">\r\n\t\t\t<a class=\"products-print__item c-button c-button--small c-button--primary\" href=\"javascript:void(0)\" onclick=\"window.print();return false;\">Print<\/a>\r\n\t\t<\/div>\r\n\t\t<div class=\"u-mb-60\"><img src=\"\/en\/wp-content\/uploads\/2022\/06\/img_vim-02.jpg\" alt=\"\"><\/div>\r\n\t\t<h4 class=\"c-headline04\">Basic specifications<\/h4>\r\n\t\t\t<table class=\"c-table c-table-col3\">\r\n\t\t\t\t<thead>\r\n\t\t\t\t\t<tr>\r\n\t\t\t\t\t\t<th>Model<\/th>\r\n\t\t\t\t\t\t<th>VIM-02<\/th>\r\n\t\t\t\t\t<\/tr>\r\n\t\t\t\t<\/thead>\r\n\t\t\t<tr>\r\n\t\t\t\t<th>Number of channels<\/th>\r\n\t\t\t\t<td>\r\n\t\t\t\t\t<p class=\"c-text\">Precharge 8 channels<br>\r\n\t\t\t\t\tPre-Sork 8 channels<br>\r\n\t\t\t\t\tMeasure  8 channels<br>\r\n\t\t\t\t\tDischarge 8 channels<\/p>\r\n\t\t\t\t<\/td>\r\n\t\t\t<\/tr>\r\n\t\t\t<tr>\r\n\t\t\t\t<th>Charging voltage<\/th>\r\n\t\t\t\t<td>\r\n\t\t\t\t\t<p class=\"c-text\">1.0 to 99.9V \u00b10.5%FS (0.1V step)<br>\r\n\t\t\t\t\t\u203bMinimum voltage for 0mA output is 3.0V (to GND)<br>\r\n\t\t\t\t\tMinimum voltage for 300mA output is 30V (to GND)<br>\r\n\t\t\t\t\t100 to 1000V \u00b10.5%FS (1V step)<\/p>\r\n\t\t\t\t<\/td>\r\n\t\t\t<\/tr>\r\n\t\t\t<tr>\r\n\t\t\t\t<th>Charging current<\/th>\r\n\t\t\t\t<td>\r\n\t\t\t\t\t<p class=\"c-text\">1.0V to 100V \uff1a2mA to 300mA\u00b15%\u00b10.5mA<br>\r\n\t\t\t\t\t101V to 200V \uff1a2mA to 150mA\u00b15%\u00b10.5mA<br>\r\n\t\t\t\t\t201V to 400V \uff1a2mA to 75mA\u00b15%\u00b10.5mA<br>\r\n\t\t\t\t\t401V to 600V \uff1a2mA to 50mA\u00b15%\u00b10.5mA<br>\r\n\t\t\t\t\t601V to 1000V \uff1a2mA to 30mA\u00b15%\u00b10.5mA<br>\r\n\t\t\t\t\tSetting resolution 1mA <\/p>\r\n\t\t\t\t<\/td>\r\n\t\t\t<\/tr>\r\n\t\t\t<tr>\r\n\t\t\t\t<th>Input Resistance<\/th>\r\n\t\t\t\t<td>\r\n\t\t\t\t\t<p class=\"c-text\">Precharge 10\u03a9\u00b110%<br>\r\n\t\t\t\t\tMeasure 1k\u03a9\u00b110%<\/p>\r\n\t\t\t\t<\/td>\r\n\t\t\t<\/tr>\r\n\t\t\t<tr>\r\n\t\t\t\t<th>Charging time (setting time)<\/th>\r\n\t\t\t\t<td>\r\n\t\t\t\t\t<p class=\"c-text\">10ms to 999ms Setup Unit 1msec<\/p>\r\n\t\t\t\t<\/td>\r\n\t\t\t<\/tr>\r\n\t\t\t<tr>\r\n\t\t\t\t<th>Leakage current measurement range<\/th>\r\n\t\t\t\t<td>\r\n\t\t\t\t\t<p class=\"c-text\">10nA, 100nA, 1uA, 10uA, 100uA, 1mA, 10mA<\/p>\r\n\t\t\t\t<\/td>\r\n\t\t\t<\/tr>\r\n\t\t\t<tr>\r\n\t\t\t\t<th>Leakage current measurement accuracy<\/th>\r\n\t\t\t\t<td>\r\n\t\t\t\t\t<p class=\"c-text\">\u00b11%FS<\/p>\r\n\t\t\t\t<\/td>\r\n\t\t\t<\/tr>\r\n\t\t\t<tr>\r\n\t\t\t\t<th>Post-discharge potential<\/th>\r\n\t\t\t\t<td>\r\n\t\t\t\t\t<p class=\"c-text\">+1V to \uff0d5V \u00b10.1V (1V step)<\/p>\r\n\t\t\t\t<\/td>\r\n\t\t\t<\/tr>\r\n\t\t\t<tr>\r\n\t\t\t\t<th>Discharge current<\/th>\r\n\t\t\t\t<td>\r\n\t\t\t\t\t<p class=\"c-text\">30mA\/50mA \u00b15%<\/p>\r\n\t\t\t\t<\/td>\r\n\t\t\t<\/tr>\r\n\t\t\t<tr>\r\n\t\t\t\t<th>Contact Detection<\/th>\r\n\t\t\t\t<td>\r\n\t\t\t\t\t<p class=\"c-text\">\u22670.1pF<\/p>\r\n\t\t\t\t<\/td>\r\n\t\t\t<\/tr>\r\n\t\t\t<tr>\r\n\t\t\t\t<th>Supported PC<\/th>\r\n\t\t\t\t<td>\r\n\t\t\t\t\t<p class=\"c-text\">OS\uff1aMicrosoft Windows 7 Professioanl(32 bit) Windows 10 IoT (64bit)<br>\r\n\t\t\t\t\tConnection Port\uff1aUSB2.0 1port<\/p>\r\n\t\t\t\t<\/td>\r\n\t\t\t<\/tr>\r\n\t\t\t<tr>\r\n\t\t\t\t<th>Power Supply<\/th>\r\n\t\t\t\t<td>\r\n\t\t\t\t\t<p class=\"c-text\">AC200V\u00b110%<\/p>\r\n\t\t\t\t<\/td>\r\n\t\t\t<\/tr>\r\n\t\t\t<tr>\r\n\t\t\t\t<th>Operating environment<\/th>\r\n\t\t\t\t<td>\r\n\t\t\t\t\t<p class=\"c-text\">10&#8451; to 40&#8451;<br>\r\n\t\t\t\t\t10% to 75%RH <span class=\"c-notes\">\u203bNo condensation<\/span><br>\r\n\t\t\t\t\tIndoor use only.<br>\r\n\t\t\t\t\tDo not use in environments where conductive contaminants are present.<\/p>\r\n\t\t\t\t<\/td>\r\n\t\t\t<\/tr>\r\n\t\t<\/table>\r\n\r\n\t\t<a href=\"\/en\/introduction_procedure\" class=\"c-button c-button--primary u-m-auto u-mt-80\">Flow of introduction<\/a>\r\n\t<\/div>\r\n<\/div>","protected":false},"excerpt":{"rendered":"Voltmeter VIM-02 The VIM-02 withstand voltage meter is the ideal instrument for measuring leakage currents in  [&hellip;]","protected":false},"author":1,"featured_media":0,"parent":123,"menu_order":2,"comment_status":"closed","ping_status":"closed","template":"template-level3.php","meta":[],"acf":[],"aioseo_notices":[],"wps_subtitle":"","_links":{"self":[{"href":"https:\/\/www.humo.co.jp\/en\/wp-json\/wp\/v2\/pages\/2284"}],"collection":[{"href":"https:\/\/www.humo.co.jp\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.humo.co.jp\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.humo.co.jp\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.humo.co.jp\/en\/wp-json\/wp\/v2\/comments?post=2284"}],"version-history":[{"count":7,"href":"https:\/\/www.humo.co.jp\/en\/wp-json\/wp\/v2\/pages\/2284\/revisions"}],"predecessor-version":[{"id":2294,"href":"https:\/\/www.humo.co.jp\/en\/wp-json\/wp\/v2\/pages\/2284\/revisions\/2294"}],"up":[{"embeddable":true,"href":"https:\/\/www.humo.co.jp\/en\/wp-json\/wp\/v2\/pages\/123"}],"wp:attachment":[{"href":"https:\/\/www.humo.co.jp\/en\/wp-json\/wp\/v2\/media?parent=2284"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}