{"id":198,"date":"2018-02-13T11:53:59","date_gmt":"2018-02-13T02:53:59","guid":{"rendered":"http:\/\/ctc-230148001434.kir.jp\/_assets\/?page_id=198"},"modified":"2020-05-27T17:27:34","modified_gmt":"2020-05-27T08:27:34","slug":"hit-250","status":"publish","type":"page","link":"https:\/\/www.humo.co.jp\/en\/products\/measuring_instrument\/hit-250","title":{"rendered":"HIT-250"},"content":{"rendered":"<script src=\"\/\/j.wovn.io\/1\" data-wovnio=\"key=LGpBTi\" async><\/script>\r\n<div class=\"content-main\">\r\n\t<div class=\"content-inner\">\r\n\t\t<h3 class=\"c-headline02\">Withstand voltage gauge for insulation test HIT-250<\/h3>\r\n\t\t<p class=\"c-text u-mb-50\">An insulation test can be performed with a maximum of 250 V when using internal power supply and a maximum of 1 kV when using external power supply. Although it is a 2-terminal connection, contact check is possible. Insulation measurement between crystal terminals and insulation measurement between package and terminals are possible without an external switching relay.<\/p>\r\n\t\t<div class=\"products-print u-mb-40\">\r\n\t\t\t<a class=\"products-print__item c-button c-button--small c-button--primary\" href=\"javascript:void(0)\" onclick=\"window.print();return false;\">Print<\/a>\r\n\t\t<\/div>\r\n\t\t<div class=\"u-mb-60\"><img src=\"\/en\/wp-content\/uploads\/2018\/02\/img_hit-250_01.png\" alt=\"\"><\/div>\r\n\r\n\t\t<h4 class=\"c-headline04\">basic specifications<\/h4>\r\n\t\t<table class=\"c-table\">\r\n\t\t\t<tr>\r\n\t\t\t\t<th>Number of channels<\/th>\r\n\t\t\t\t<td>\r\n\t\t\t\t\t<p class=\"c-text\">1<\/p>\r\n\t\t\t\t<\/td>\r\n\t\t\t<\/tr>\r\n\t\t\t<tr>\r\n\t\t\t\t<th>Output voltage<\/th>\r\n\t\t\t\t<td>\r\n\t\t\t\t\t<p class=\"c-text\">DC 1 to 250 V \u00b1 1% \u00b1 0.3 V<br>\r\n\t\t\t\t\tExternal power input DC 1 to 1 kV 5 mA max<\/p>\r\n\t\t\t\t<\/td>\r\n\t\t\t<\/tr>\r\n\t\t\t<tr>\r\n\t\t\t\t<th>Time to calculate<\/th>\r\n\t\t\t\t<td>\r\n\t\t\t\t\t<p class=\"c-text\">50 ms to 9999 ms<\/p>\r\n\t\t\t\t<\/td>\r\n\t\t\t<\/tr>\r\n\t\t\t<tr>\r\n\t\t\t\t<th>Charging current<\/th>\r\n\t\t\t\t<td>\r\n\t\t\t\t\t<p class=\"c-text\">5 mA \u00b1 2 mA<\/p>\r\n\t\t\t\t<\/td>\r\n\t\t\t<\/tr>\r\n\t\t\t<tr>\r\n\t\t\t\t<th>Measurement accuracy<\/th>\r\n\t\t\t\t<td>\r\n\t\t\t\t\t<p class=\"c-text\">Depending on the current flowing through the object to be measured, the range is as follows<br>\r\n\t\t\t\t\t\u00b7 100 pA to 1 nA: \u00b1 10%<br>\r\n\t\t\t\t\t\u00b7 1 mA to 10 nA: \u00b1 3%<br>\r\n\t\t\t\t\t\u00b7 10 nA to 100 \u03bcA: \u00b1 1%<\/p>\r\n\t\t\t\t<\/td>\r\n\t\t\t<\/tr>\r\n\t\t\t<tr>\r\n\t\t\t\t<th>Contact detection range\t<\/th>\r\n\t\t\t\t<td>\r\n\t\t\t\t\t<p class=\"c-text\">0.1 pF or more<\/p>\r\n\t\t\t\t<\/td>\r\n\t\t\t<\/tr>\r\n\t\t\t<tr>\r\n\t\t\t\t<th>Contact detection frequency<\/th>\r\n\t\t\t\t<td>\r\n\t\t\t\t\t<p class=\"c-text\">1.9 MHz to 2.1 MHz<\/p>\r\n\t\t\t\t<\/td>\r\n\t\t\t<\/tr>\r\n\t\t\t<tr>\r\n\t\t\t\t<th>Input terminal<\/th>\r\n\t\t\t\t<td>\r\n\t\t\t\t\t<p class=\"c-text\">BNC or SHV<\/p>\r\n\t\t\t\t<\/td>\r\n\t\t\t<\/tr>\r\n\t\t\t<tr>\r\n\t\t\t\t<th>Measurement mode<\/th>\r\n\t\t\t\t<td>\r\n\t\t\t\t\t<p class=\"c-text\">Mode AB: Input terminal A to B<br>\r\n\t\t\t\t\tMode C &#8211; AB: Between input terminal C to A + B<\/p>\r\n\t\t\t\t<\/td>\r\n\t\t\t<\/tr>\r\n\t\t\t<tr>\r\n\t\t\t\t<th>Interface<\/th>\r\n\t\t\t\t<td>\r\n\t\t\t\t\t<p class=\"c-text\">USB + DI \/ O<\/p>\r\n\t\t\t\t<\/td>\r\n\t\t\t<\/tr>\r\n\t\t\t<tr>\r\n\t\t\t\t<th>Input power supply<\/th>\r\n\t\t\t\t<td>\r\n\t\t\t\t\t<p class=\"c-text\">AC 100 to 200 V 50\/60 Hz (AC adapter DC 5 V 2 A included)<\/p>\r\n\t\t\t\t<\/td>\r\n\t\t\t<\/tr>\r\n\t\t\t<tr>\r\n\t\t\t\t<th>Dimension<\/th>\r\n\t\t\t\t<td>\r\n\t\t\t\t\t<p class=\"c-text\">160 (W) x 99 (D) x 230 (H) mm<\/p>\r\n\t\t\t\t<\/td>\r\n\t\t\t<\/tr>\r\n\t\t<\/table>\r\n\r\n\t\t<a href=\"\/en\/introduction_procedure\" class=\"c-button c-button--primary u-m-auto u-mt-80\">Flow of introduction<\/a>\r\n\t<\/div>\r\n<\/div>","protected":false},"excerpt":{"rendered":"Withstand voltage gauge for insulation test HIT-250 An insulation test can be performed with a maximum of 250  [&hellip;]","protected":false},"author":1,"featured_media":0,"parent":123,"menu_order":47,"comment_status":"closed","ping_status":"closed","template":"template-level3.php","meta":[],"acf":[],"aioseo_notices":[],"wps_subtitle":"","_links":{"self":[{"href":"https:\/\/www.humo.co.jp\/en\/wp-json\/wp\/v2\/pages\/198"}],"collection":[{"href":"https:\/\/www.humo.co.jp\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.humo.co.jp\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.humo.co.jp\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.humo.co.jp\/en\/wp-json\/wp\/v2\/comments?post=198"}],"version-history":[{"count":10,"href":"https:\/\/www.humo.co.jp\/en\/wp-json\/wp\/v2\/pages\/198\/revisions"}],"predecessor-version":[{"id":2132,"href":"https:\/\/www.humo.co.jp\/en\/wp-json\/wp\/v2\/pages\/198\/revisions\/2132"}],"up":[{"embeddable":true,"href":"https:\/\/www.humo.co.jp\/en\/wp-json\/wp\/v2\/pages\/123"}],"wp:attachment":[{"href":"https:\/\/www.humo.co.jp\/en\/wp-json\/wp\/v2\/media?parent=198"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}