{"id":194,"date":"2018-02-13T11:52:21","date_gmt":"2018-02-13T02:52:21","guid":{"rendered":"http:\/\/ctc-230148001434.kir.jp\/_assets\/?page_id=194"},"modified":"2020-05-27T17:55:12","modified_gmt":"2020-05-27T08:55:12","slug":"hxa-220a","status":"publish","type":"page","link":"https:\/\/www.humo.co.jp\/en\/products\/measuring_instrument\/hxa-220a","title":{"rendered":"HXA-220A"},"content":{"rendered":"<script src=\"\/\/j.wovn.io\/1\" data-wovnio=\"key=LGpBTi\" async><\/script>\r\n<div class=\"content-main\">\r\n\t<div class=\"content-inner\">\r\n\t\t<h3 class=\"c-headline02\">Crystal Analyzer HXA-220A<\/h3>\r\n\t\t<p class=\"c-text u-mb-50\">Crystal Analyzer HXA &#8211; 220A is the most suitable instrument for measuring the frequency characteristics of crystal units and passive components.<br>\r\n\t\tSince USB is used for connection with a computer, you do not choose a computer to use.<\/p>\r\n\t\t<div class=\"products-print u-mb-40\">\r\n\t\t\t<a class=\"products-print__item c-button c-button--small c-button--primary\" href=\"javascript:void(0)\" onclick=\"window.print();return false;\">Print<\/a>\r\n\t\t<\/div>\r\n\t\t<div class=\"u-mb-60\"><img src=\"\/en\/wp-content\/uploads\/2018\/02\/img_hxa-220a_01.png\" alt=\"\"><\/div>\r\n\r\n\t\t<h4 class=\"c-headline04\">basic specifications<\/h4>\r\n\t\t<table class=\"c-table\">\r\n\t\t\t<tr>\r\n\t\t\t\t<th>Frequency characteristic<\/th>\r\n\t\t\t\t<td>\r\n\t\t\t\t\t<p class=\"c-text\">Range: 30 kHz to 220 MHz<br>\r\n\t\t\t\t\tSetting resolution: 1 mHz (30 kHz to 300 kHz) \/ 1 Hz (300 kHz to 220 MHz)<br>\r\n\t\t\t\t\tAccuracy: \u00b1 1 ppm<\/p>\r\n\t\t\t\t<\/td>\r\n\t\t\t<\/tr>\r\n\t\t\t<tr>\r\n\t\t\t\t<th>Output characteristics<\/th>\r\n\t\t\t\t<td>\r\n\t\t\t\t\t<p class=\"c-text u-mb-10\">Range:<br>\r\n\t\t\t\t\t+ 8 dBm to -43 dBm (30 kHz to 300 kHz)<br>\r\n\t\t\t\t\t+10 dBm to -43 dBm (300 kHz to 1 MHz)<br>\r\n\t\t\t\t\t+18 dBm to -43 dBm (1 MHz to 200 MHz)<br>\r\n\t\t\t\t\t+10 dBm to -43 dBm (200 MHz to 220 MHz)<br>\r\n\t\t\t\t\t0.1 dBm resolution<\/p>\r\n\t\t\t\t\t<p class=\"c-text\">Range setting: Start \/ Stop, or center \/ span<br>\r\n\t\t\t\t\tSweep rate: Up to 100 \u03bcs \/ point<br>\r\n\t\t\t\t\tMeasurement point: 1601 points<br>\r\n\t\t\t\t\tOutput port: SMA (Female), 50 \u03a9 connector<\/p>\r\n\t\t\t\t<\/td>\r\n\t\t\t<\/tr>\r\n\t\t\t<tr>\r\n\t\t\t\t<th>Input characteristics<\/th>\r\n\t\t\t\t<td>\r\n\t\t\t\t\t<p class=\"c-text u-mb-10\">Frequency range: same as signal source characteristics<br>\r\n\t\t\t\t\tAverage noise level:<br>\r\n\t\t\t\t\t-70 dBm (30 kHz to 1 MHz)<br>\r\n\t\t\t\t\t-85 dBm (1 MHz to 100 MHz)<br>\r\n\t\t\t\t\t-70 dBm (100 MHz to 220 MHz)<\/p>\r\n\t\t\t\t\t<p class=\"c-text\">Resolution bandwidth: 10 Hz to 15 kHz (1, 1.5, 2, 3, 4, 5, 7 steps)<br>\r\n\t\t\t\t\tInput port: SMA (Female), 50 \u03a9 connector<\/p>\r\n\t\t\t\t<\/td>\r\n\t\t\t<\/tr>\r\n\t\t\t<tr>\r\n\t\t\t\t<th>Error correction function\/th>\r\n\t\t\t\t<td>\r\n\t\t\t\t\t<p class=\"c-text\">Normalize, Trans Full Cal (l Full Cal: l Open, Short, Load)<\/p>\r\n\t\t\t\t<\/td>\r\n\t\t\t<\/tr>\r\n\t\t\t<tr>\r\n\t\t\t\t<th>Operable PC<\/th>\r\n\t\t\t\t<td>\r\n\t\t\t\t\t<p class=\"c-text\">OS: Microsoft Windows 7 Professioanl (32 bit)<br>\r\n\t\t\t\t\tConnection port: USB 2.0 1 port<\/p>\r\n\t\t\t\t<\/td>\r\n\t\t\t<\/tr>\r\n\t\t\t<tr>\r\n\t\t\t\t<th>Power Supply<\/th>\r\n\t\t\t\t<td>\r\n\t\t\t\t\t<p class=\"c-text\">DC + 24 V \u00b1 2 V \/ connector 39 &#8211; 29 &#8211; 1028 (manufactured by Molex)<\/p>\r\n\t\t\t\t<\/td>\r\n\t\t\t<\/tr>\r\n\t\t\t<tr>\r\n\t\t\t\t<th>External dimensions<\/th>\r\n\t\t\t\t<td>\r\n\t\t\t\t\t<p class=\"c-text\">260 (W) x 150 (L) x 30 (H) mm<span class=\"c-notes\">* Excluding protrusions<\/span><\/p>\r\n\t\t\t\t<\/td>\r\n\t\t\t<\/tr>\r\n\t\t\t<tr>\r\n\t\t\t\t<th>Operating environment<\/th>\r\n\t\t\t\t<td>\r\n\t\t\t\t\t<p class=\"c-text\">10&#8451; \uff5e 40&#8451;<br>\r\n\t\t\t\t\t15% to 80% RH <span class=\"c-notes\">* No condensation<\/span><\/p>\r\n\t\t\t\t<\/td>\r\n\t\t\t<\/tr>\r\n\t\t<\/table>\r\n\r\n\t\t<a href=\"\/en\/introduction_procedure\" class=\"c-button c-button--primary u-m-auto u-mt-80\">Flow of introduction<\/a>\r\n\t<\/div>\r\n<\/div>","protected":false},"excerpt":{"rendered":"Crystal Analyzer HXA-220A Crystal Analyzer HXA &#8211; 220A is the most suitable instrument for measuring the  [&hellip;]","protected":false},"author":1,"featured_media":0,"parent":123,"menu_order":45,"comment_status":"closed","ping_status":"closed","template":"template-level3.php","meta":[],"acf":[],"aioseo_notices":[],"wps_subtitle":"","_links":{"self":[{"href":"https:\/\/www.humo.co.jp\/en\/wp-json\/wp\/v2\/pages\/194"}],"collection":[{"href":"https:\/\/www.humo.co.jp\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.humo.co.jp\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.humo.co.jp\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.humo.co.jp\/en\/wp-json\/wp\/v2\/comments?post=194"}],"version-history":[{"count":10,"href":"https:\/\/www.humo.co.jp\/en\/wp-json\/wp\/v2\/pages\/194\/revisions"}],"predecessor-version":[{"id":2145,"href":"https:\/\/www.humo.co.jp\/en\/wp-json\/wp\/v2\/pages\/194\/revisions\/2145"}],"up":[{"embeddable":true,"href":"https:\/\/www.humo.co.jp\/en\/wp-json\/wp\/v2\/pages\/123"}],"wp:attachment":[{"href":"https:\/\/www.humo.co.jp\/en\/wp-json\/wp\/v2\/media?parent=194"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}